PN3001
Pressure sensor with display
PN-250-SBR14-MFPKG/US/ /V
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PN3001-01 — 06.09.2010
Outputs
Total number of outputs
2
Output signal
switching signal; analogue signal; (configurable)
Electrical design
PNP
Number of digital outputs
1
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching
output DC
[V]
2
Permanent current rating of
switching output DC
[mA]
250
Switching frequency DC [Hz]
< 170
Number of analogue outputs
1
Analogue current output [mA]
4...20
Max. load [Ω]
500
Analogue voltage output [V]
0...10
Min. load resistance [Ω]
2000
Short-circuit protection
yes
Type of short-circuit
protection
pulsed
Measuring/setting range
Measuring range 0...250 bar 0...3625 psi 0...25 MPa
Set point SP 2...250 bar 40...3620 psi 0.2...25 MPa
Reset point rP 1...249 bar 20...3600 psi 0.1...24.9 MPa
In steps of 1 bar 20 psi 0.1 MPa
Factory setting SP1 = 63 bar rP1 = 58 bar
Accuracy / deviations
Switch point accuracy
[% of the span]
< ± 0,5
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation
[% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation
[% of the span]
< ± 0,25
Long-term stability
[% of the span]
< ± 0,05; (per 6 months)
Temperature coefficient zero
point
[% of the span / 10 K]
0,2; (0...80 °C)
Temperature coefficient span
[% of the span / 10 K]
0,2; (0...80 °C)
Response times
Delay time programmable dS,
dr
[s]
0; 0,2...50
Max. response time analogue
output
[ms]
3